For potassium sodium feldspar PTMS MAGNETIC SEPARATOR iron removal equipment, magnetic system is the core component. Check whether the magnetic field strength of the magnetic system is normal, and professional testing equipment such as Gaussian meter can be used for measurement. If the magnetic field strength of the equipment should be 13000 Gaussian, but the detection finds that the magnetic field strength is significantly lower than this value, the magnet may be aging, damaged or the magnetic circuit failure.
If magnets in the magnetic system are affected by adverse factors such as impact or high temperature, they may lead to weakened magnetism. Check the magnet and ensure the magnet is firmly installed inside the device. During the PTMS MAGNETIC SEPARATOR operation, it may damage the magnet itself, and on the other hand, it will also affect the magnetic selection effect, resulting in incomplete iron removal.
Check the rotation of the PTMS MAGNETIC SEPARATOR drum, including whether the normal drum speed and whether the rotation is smooth. It can be judged by observing the rotation of the drum and the coordination with the transmission device. If the drum speed is abnormal, it may be caused by motor failure, transmission belt skid, or mechanical failure of the drum itself.